Division B - 3.1.15.2.(4)
NBC 2020 requires Class A roof covering only when the building heights is greater than 25 m. Current proposed change would require Class A regardless of building height (in meters).

Proposed Change:
Use exact wording for NBC 2020 as below.
(4) Roof coverings in buildings or parts of buildings permitted to be of encapsulated mass timber construction shall have a Class A classification [*where the roof height is greater than 25 m measured from the floor of the first storey to the highest point of the roof*].

Rationale:
The intent of the proposed change to the OBC is to provide greater harmonization with the National Building Codes. Deleting national provisions does not meet Ontario's objective of harmonizing with NBC.