Comment
Division B - 3.1.5.5 and 3.1.5.6
Significant changes have been made in the NBC 2020 Appendix D with respect to exterior walls having combustible cladding or elements, namely the new NBC 2020 Appendix D-6 in which generic exterior wall assemblies deemed to satisfy the criteria of CAN/ULC S134 stipulated in 3.1.5.5.(1)(b) have been added.
Below are clauses taken from NBC 2020:
3.1.5.5.(4) An exterior wall assembly constructed in conformance with Appendix D-6–2020 is deemed to satisfy the criteria of Clause (1)(b).
3.1.5.6.(2) An exterior wall assembly constructed in conformance with Appendix D-6–2020 is deemed to satisfy the criteria of Subclause (1)(b)(i).
It is fundamental that MMAH Supplementary Standard SB-2 "Fire Performance Ratings" is also updated accordingly. SB-2 is not available for review.
Submitted March 11, 2022 9:46 AM
Comment on
Proposed Changes for the Next Edition of Ontario’s Building Code (Winter Consultation)
ERO number
019-4974
Comment ID
60028
Commenting on behalf of
Comment status