Division B - 3.1.5.5 and 3.1…

ERO number

019-4974

Comment ID

60028

Commenting on behalf of

FPInnovations

Comment status

Comment approved More about comment statuses

Comment

Division B - 3.1.5.5 and 3.1.5.6
Significant changes have been made in the NBC 2020 Appendix D with respect to exterior walls having combustible cladding or elements, namely the new NBC 2020 Appendix D-6 in which generic exterior wall assemblies deemed to satisfy the criteria of CAN/ULC S134 stipulated in 3.1.5.5.(1)(b) have been added.

Below are clauses taken from NBC 2020:
3.1.5.5.(4) An exterior wall assembly constructed in conformance with Appendix D-6–2020 is deemed to satisfy the criteria of Clause (1)(b).

3.1.5.6.(2) An exterior wall assembly constructed in conformance with Appendix D-6–2020 is deemed to satisfy the criteria of Subclause (1)(b)(i).

It is fundamental that MMAH Supplementary Standard SB-2 "Fire Performance Ratings" is also updated accordingly. SB-2 is not available for review.