Comments

View the comments this notice received through the registry. You can either download them all or search and sort below.

Some comments will not be posted online. Learn more about the comment status and our comment and privacy policies.

Download comments

Search comments

Comment ID

59964

Commenting on behalf of

Individual

Comment status

Comment approved More about comment statuses
• Please update and enhance existing bird deterrent guidelines to reflect current scientific data and change the status of these guidelines from guideline to mandatory. • Consistently or regularly update building codes as new data is collected. Read more

Comment ID

59977

Commenting on behalf of

Individual

Comment status

Comment approved More about comment statuses
As a resident of City where the climate lens has not yet been applied to all municipal decisions, I am deeply concerned that their building codes will not be stringent enough. For example, eliminating the use of fossil fuels for space and hot water heating . Read more

Comment ID

59985

Commenting on behalf of

IPEX Management Inc.

Comment status

Comment approved More about comment statuses
The proposed Clause 3.1.9.4(5) appears to contradict the requirements for fire-stopping of combustible penetrations contained in Clause 3.1.9.1 and 3.1.9.4(4) where combustible DWV is permitted on both sides of a (vertical) fire separation. Read more

Comment ID

59986

Commenting on behalf of

IPEX Management Inc.

Comment status

Comment approved More about comment statuses
The proposed Clause 3.1.9.4(7) mandates that regardless of whether the penetrating item material is combustible or noncombustible pipe, the penetration would require a firestop with a 50Pa pressure differential. Read more

Comment ID

59987

Commenting on behalf of

IPEX Management Inc.

Comment status

Comment approved More about comment statuses
The current Ontario 2015 Clause 3.1.9.4 (5) allows the ability to waive the 50Pa requirement when a building is sprinklered (except as required by Sentence (7)). This has been the case in Ontario for several code cycles and has never been an issue of concern. Read more

Comment ID

59989

Commenting on behalf of

IPEX Management Inc.

Comment status

Comment approved More about comment statuses
The proposed Clause 3.1.9.4(3) allows combustible DWV penetrations by way of the exceptions permitted in Sentences (4) to (8). When comparing to Sentence (4), it appears that it trumps Sentence (3), therefore Sentence (3) is not needed and should be deleted.

Comment ID

59992

Commenting on behalf of

IPEX Management Inc.

Comment status

Comment approved More about comment statuses
9.10.9.7(3) appears to contradict the requirements for fire-stopping of combustible penetrations contained in Clause 9.10.9.6. Clause 9.10.9.6 mandates firestopping for penetrations and does not limit the combustible pipe to one side of a fire penetration. Read more

Comment ID

59996

Commenting on behalf of

Individual

Comment status

Comment approved More about comment statuses
As a member of the Energy & Environment committee for the City of Stratford, I am concerned about the new Ontario Building Code. We need a tiered code that clearly outlines a time frame for advancements to higher tiers. Read more

Comment ID

59998

Commenting on behalf of

Individual

Comment status

Comment approved More about comment statuses
Dear Ministry of Municipal Affairs and Housing, These comments relate to Ontario’s 2022 Winter consultation for review of the Ontario Building Code, related to changes in 2020 National Building Code. Read more

Comment ID

59999

Commenting on behalf of

Individual

Comment status

Comment approved More about comment statuses
The Ontario Building Code has been invaluable in ensuring that Ontario citizens live in safe buildings, in spite of grumbling from the construction sector that the requirements drive up their costs. Safety was judged to be more important. Read more

Comment ID

60006

Commenting on behalf of

Individual

Comment status

Comment approved More about comment statuses
I am concerned because the Ontario Building Code currently lacks provisions to ensure that bird-friendly construction measures are used. Data show that collisions with glass windows in buildings are a leading cause of migratory bird deaths in Ontario and contributes to biodiversity loss. Read more

Comment ID

60011

Commenting on behalf of

Individual

Comment status

Comment approved More about comment statuses
I absolutely believe that buildings in Ontario need to be bird-friendly. I support all of the accessibility needs that need to take place for humans, but birds also matter and we should construct buildings that are safe for them in order to prevent unintended collisions and population decline. Read more

Comment ID

60012

Commenting on behalf of

Efficiency Canada

Comment status

Comment approved More about comment statuses
Efficiency Canada is the national voice for an energy efficient economy. Our mission is to create a sustainable environment and better life for all Canadians by making our country a global leader in energy efficiency policy, technology, and jobs. Read more